Tóm tắt

Hydrogen-fueled engines with external mixture formation have potentially high thermal efficiency because of a more homogeneous inlet mixture. In addition, the structure of such engines is relatively simple. The practical use of hydrogen can be visible in the short term. The occurrence of backfire at high engine load conditions, however, is an important problem. Because of this, the method of attaining both high efficiency and high power without backfire in a hydrogen-fueled engine is the most important key. The backfire phenomena of hydrogen-air mixtures in the intake system are often a result of backflow of a pre-ignited fast flame from combustion chamber during the valve overlap period. When the valve overlap period is short enough, backfire may not occur even under high load operating conditions due to the fact that the pre-ignited flame cannot flow backward into the inlet system. The reduction of the valve overlap period, therefore, is used to prevent the occurrence of backfire, but this has not been clearly demonstrated yet. In addition, the change of the valve overlap period to control backfire and to realize the concept of obtaining both high efficiency and high power (by supercharging) in a hydrogen-fueled engine has not been reported yet. In this research, the change of the valve timings is used to study the feasibility of preventing backfire occurrence and to realize the concept of attaining both high power and higher efficiency without backfire in a hydrogen-fueled engine with external injection. Key information to achieve the above objectives is as follows. Firstly, due to the change of the VOP is used to determine the possibility of backfire control, a Mechanical Continuous Variable Valve Timing (MCVVT) system (to change the timings of mechanical valves) equipped with a hydrogen-fueled engine with external injection are researched and developed. Secondly, the change of the valve overlap period is to evaluate the possibility of preventing backfire and to imply the main prevention factor of backfire control. Thirdly, the change of the valve overlap period is used to quantify overall engine performances. Finally, the feasibility of the concept of obtaining high power and high efficiency without backfire is determined by supercharging at lean mixture ratio of around 0.5 (where the maximum thermal efficiency occurs) and the intake valve opening timing is located at TDC for avoiding backfire. Intake and exhaust valves MCVVT system is equipped with the same structure. Each system can adjust the intake and exhaust valve opening/closing timings in each period to vary the values of the valve overlap period (VOP). Hydrogen-fueled research engine equipped with MCVVT system has larger mechanical loss than that without MCVVT system when the engine speed increases. This loss, however, is interpreted to have not affected of backfire control by changing the valve timings. The possibility of controlling backfire is studied by changing the VOP in a wide range from 50CA to zero (where the exhaust valve closing timing is located at 10aTDC). When the VOP reduces from 50CA to 10CA, the backfire limit (BFL) equivalence ratio increases continuously. When the VOP is reduced lower VOP 10CA, the BFL equivalence ratio is expanded from 0.3 to over 1.0 without backfire. This means that the BFL equivalence ratio is significantly increased with reduction of the VOP. The reason here may be caused by the decrease of supplied energy when the valve overlap period reduces. Thus, the variation of the BFL equivalence ratio is examined in the cases of equal supplied energy. It shows the same results. This implies that when the VOP reduces, the increase of BFL equivalence ratio is affected by rather from the reduction of backflow period than the decrease of supplied energy. The feasibility of backfire prevention is verified by changing the VOP center (the fixed VOP of the intake valve opening timing and the exhaust valve closing timing to be chang
Bản toàn văn lưu tại thư viện Đại học Quốc gia TP. Hồ Chí Minh

Thông tin và tóm tắt ở trên lấy từ kho số mở của thư viện trường. Bản toàn văn do thư viện trường quản lý — có nơi cho đọc trực tuyến, có nơi cần tài khoản bạn đọc của trường.

Mở tại thư viện trường ↗
Dùng tài liệu tham khảo cho đúng
  • Đọc để hiểu cách người trước đặt câu hỏi, chọn phương pháp, trình bày số liệu — rồi tự làm với dữ liệu và bối cảnh của bạn.
  • Ý, số liệu, bảng biểu lấy từ tài liệu này phải trích dẫn (tác giả, năm, tên đề tài, cơ sở đào tạo).
  • Đề tài trùng tên vẫn làm được nếu khác đơn vị khảo sát, thời gian hoặc cách tiếp cận — nêu rõ điểm khác trong phần mở đầu.

Hướng dẫn chọn đề tài, cấu trúc và số liệu cho ngành này: Luận văn kỹ thuật, xây dựng, môi trường · Hỏi đáp từng chương với người hướng dẫn số: Học Giả Số · Công cụ số: Luận Văn Số.

Đề tài cùng ngành

Tác giả muốn gỡ, sửa thông tin hoặc bổ sung bản toàn văn: gửi yêu cầu qua trang Liên hệ, kèm đường dẫn trang này.